LD Airotor Led Push Button Handpiece (No Warranty)
LED Handpiece Push Button handpiece
(No Warranty)
LD-392
Out of stock
₹4,200.00
(Price Per Pack Inclusive of GST)
LD Airotor Led Push Button Handpiece (No Warranty)
Presentation :
- LED handpiece integrate E-generator 1piece
- Cap wrench 1 piece
- O-RING 1 set
- Cartridge 1 piece
- Operation Manual 1 sheet
- Needle 1 sheet
Description : - Self-suffcient power system instead of extra supply
- Clear view with day-light LED illumination
- Triple spray
- Push button system
Technical Parameter for dental handpiece:
Operating pressure: 0.25Mpa-0.3Mpa(0.3Mpa preferred)
Air consumption : 55L/min
Free-load speed : 25,000 30000 r.p.m.
Chucking power : 20-45N
Noise : <70db
Net Weight : 88 Gms
Execution according to ISO 7785-1
Utlllty range :
For dental operation drilling and polishing
Usage method :
- Cartridge replacement unscrew the cap and take out the cartridge install a new cartridge put the cartridge into the cave of the head,press it Screw the cap with hands first then use the wrench to fasten it.
Attention : In order to protect the meticulous thread,please do not use the wrench at the beginning - Burs do not use unqualified bur diamond bur shafts should follow the demands of ISO standard, diameter 1.59~1.60mm
Do not use a bent,damage,or short handle bur - Replacement of bur,Press the cap and take out the bur press the cap,insert the bur,and lose the cap to prevent accident of dropping bur,and damage to bearing,bur should be inserted to the bottom.
External cleaning & maintenance :
*Clean the external side suing 70% GL alcohol or other disinfecting agent without having an ammonium or acid basis or chlorine.
*Do never immerge the handpiece in disinfection beths.
*Lubricate the turbine before each sterilization cycle handpiece which are not subject to a sterilization process must be lubricated before initialiing each work period
*Apply only original libricates from NSK
*Sterilize the handpiece and bur changer in autoclave up to 135°C 20 MINUTES WITH 121°C,and 15 minuts with 135°c withdraw handpiece from autoclave after sterilization.
Led cleaning :
Clean the LED USING 70% GL Alcohol or other disinfection agents without having an ammonium or acid basis or chlorine.
An improper care and maintenance may lead to a premature wear and failure of the handpiece
Replacement of O-ring :
Press the O-ring with thumb and index finger,move forword and take out the O-ring
Install new O-ring and spray oil to it.Do not use Vaseline and some other grease.